On the value of electrical resistivity tomography for monitoring leachate injection in solid state anaerobic digestion plants at farm scale - INRAE - Institut national de recherche pour l’agriculture, l’alimentation et l’environnement Accéder directement au contenu
Article Dans Une Revue Waste Management Année : 2016

On the value of electrical resistivity tomography for monitoring leachate injection in solid state anaerobic digestion plants at farm scale

Evaluation de l'utilisation de la tomographie de resistivité électrique appliquée à la caractérisation des injections de la lixiviat dans les digesteurs anaérobiques par voie sèche

Résumé

Agricultural waste is a valuable resource for solid state anaerobic digestion (SSAD) thanks to its high solid content (>15%). Batch mode SSAD with leachate recirculation is particularly appropriate for such substrates. However, for successful degradation, the leachate must be evenly distributed through the substrate to improve its moisture content. To study the distribution of leachate in agricultural waste, electrical resistivity tomography (ERT) was performed. First, laboratory-scale experiments were conducted to check the reliability of this method to monitor infiltration of the leachate throughout the solid. Two representative mixtures of agricultural wastes were prepared: a "winter" mixture, with cattle manure, and a "summer" mixture, with cattle manure, wheat straw and hay. The influence of density and water content on electrical resistivity variations was assessed in the two mixtures. An increase in density was found to lead to a decrease in electrical resistivity: at the initial water content, resistivity decreased from 109.7 to 19.5 Omega.m in the summer mixture and from 9.8 to 2.7 Omega.m in the "winter" mixture with a respective increased in density of 0.134-0.269, and 0.311-0.577. Similarly, resistivity decreased with an increase in water content: for low densities, resistivity dropped from 109.7 to 7.1 Omega.m and 9.8 to 4.0 Omega.m with an increase in water content from 64 to 90 w% and 74 to 93 w% for "summer" and "winter" mixtures respectively. Second, a time-lapse ERT was performed in a farm-scale SSAD plant to monitor leachate infiltration. Results revealed very heterogeneous distribution of the leachate in the waste, with two particularly moist areas around the leachate injection holes. However, ERT was successfully applied in the SSAD plant, and produced a reliable 3D map of leachate infiltration. (C) 2016 Elsevier Ltd. All rights reserved.
Fichier non déposé

Dates et versions

hal-02604836 , version 1 (16-05-2020)

Identifiants

Citer

Axelle Degueurce, Rémi Clément, S. Moreau, Pascal Peu. On the value of electrical resistivity tomography for monitoring leachate injection in solid state anaerobic digestion plants at farm scale. Waste Management, 2016, 56, pp.125-136. ⟨10.1016/j.wasman.2016.06.028⟩. ⟨hal-02604836⟩
11 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More